Wiki Page: Error - Could not find stored procedure

$
0
0
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.96 Environment: N/A Area: Database Platform Support Subarea: N/A Error or Warning Message One of the following or similar error message is displayed when attempting various operations. Internal Error Error Message: Could not find stored procedure 'GetProject_P_id'. TargetSite: Boolean CheckConn(System.Data.SqlClient.SqlException) DeclaringType: ECT.ECAD.DAL.SqlServerProject Attributes: private MemberType: Method Internal Error Error Message : Could not find stored procedure 'InitBuildConn_Page'. TargetSite: Boolean CheckConn(System.Data.SqlClient.SqlException) DeclaringType: ECT.ECAD.DAL.SqlServerProject Attributes: private MemberType: Method Internal Error Error Message: Could not find stored procedure 'MoveWirePropertyData'. TargetSite: Void OnError(System.Data.SqlClient.SqlException) DeclaringType: System.Data.SqlClient.SqlConnection Attributes: internal MemberType: Method Internal Error DB_Restore_ConvertWireProperty ProjectDB Error Message: Could not find stored procedure 'InsertWirePropertyTable'. TargetSite: Boolean _InsertTable(System.Data.DataTable, Bentley.Electrical.Data.Db.TableNames, System.Data.DataTable By Ref) DeclaringType: ECT.ECAD.DAL.BulkInsert Attributes: private MemberType: Method Explanation The error messages indicate that the project database schema is incomplete, with at least one stored procedure missing. The script that updates the schema of the project database after the software is updated drops stored procedures and recreates them. It is possible some stored procedures did not get recreated after being dropped. If the database was just created and not updated, then it was not created completely for some reason. Steps to Resolve Option 1 If the database schema was updated and the database needs to be preserved because it contains project data, update the database schema again in order to add the missing stored procedures. This must be done by running the update script "manually", since the Project Database Utility will likely determine the schema was already updated and not perform the update. See the "Update the Database Method 2: Executing a Script" section of [[Creating and Updating the Project Database]]. Option 2 If the database was recently created and contains no project data that needs to be preserved, create a new database (with a new name). See [[Creating and Updating the Project Database]]. If one method of creating the database does not work, try the other. Original Author: Matt_P Keywords: MoveWirePropertyData, GetProject_P_id, ClearSpecifiedParentDevice, restore, Project Manager, runsql

Viewing all articles
Browse latest Browse all 3874

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>