Forum Post: RE: ERROR: Exception has been thrown by the target of an invocation; HELP

$
0
0
Safiah, since all three error messages mention "MRU" (Most Recently Used), and MRU data is stored in the per-user application data folder for Substation , I would first try renaming this folder while the Bentley Substation application is closed. This will create a new folder with fresh contents (and no MRU data at first) when you start Bentley Substation. The folder to rename is the "Substation V8i" folder found by entering or pasting %APPDATA%\Bentley\Substation V8i into the address bar of Windows File Explorer (not Internet Explorer). If this does not help, you can rename the folder back to "Substation V8i".