Wiki Page: Error - SQL state S1010 Function sequence error

$
0
0
Product(s): Bentley Raceway and Cable Management Version(s): 08.11.07.xx Environment: N/A Area: Installation_Configuration Subarea: N/A Error or Warning Message An error message that includes the following text occurs frequently when updating the database: SQL state: S1010 SQL Error: [Microsoft][ODBC Driver Manager] Function sequence error How to Avoid Include "MARS_Connection=yes" in the value for BRCM_DB_CONNECTSTRING. Open the .PCF file for a problem project in Notepad Append ";MARS_Connection=yes" to the BRCM_DB_CONNECTSTRING line. For example: BRCM_DB_CONNECTSTRING=DSN=BRCMUSER;UID=BRCMUser;PWD=brcm;MARS_Connection=yes Original Author: Matt_P