Product(s): Bentley Raceway and Cable Management Version(s): 08.11.07.xx Environment: N/A Area: ProjectWise Integration Subarea: N/A Error or Warning Message The following message is displayed when trying to use certain tools in BRCM. BRCM Info Design file not registered as a BRCM file within ProjectWise. Explanation The Bentley Raceway and Cable Management software is configured to use ProjectWise, or at least ProjectWise applications have been detected, but the project is not set up in ProjectWise. How to Avoid Option 1 - configure the project in ProjectWise. See the BRCM installation guide and [[ProjectWise Configuration for BRCM]] Option 2 - disable ProjectWise integration with BRCM Open the PW.CFG file in Notepad. The typical path for this file is: C:\Program Files (x86)\Bentley\BRCM\BRCM\config\appl Uncomment the following line: #PW_DISABLE_INTEGRATION_FROM_DESKTOP=1 by removing the # so that it reads: PW_DISABLE_INTEGRATION_FROM_DESKTOP=1 Save the PW.CFG file. Since it is located in Program Files, it may be necessary to use Save As and save it in a different location such as the Desktop folder, then overwrite the original PW.CFG with it using Windows Explorer with administrator permissions. Restart Bentley Raceway and Cable Management. Original Author: Matt_P
↧