Forum Post: RE: Concatenating Project.Descriptions in Title Block Designer
There is currently an Enhancement Request to add a feature to do this. See this previous forum post:...
View ArticleForum Post: RE: Report Template Designer
Try this: (sender as XRLabel).Text = tag + Environment.NewLine + fn; You will have to set the Multiline property for the cell/label to "Yes" for this to work. The Multiline property is in the Behavior...
View ArticleWiki Page: Multi-tier Terminal Blocks
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Component Management Subarea: Create Symbol Background The typical modular terminal block has two...
View ArticleWiki Page: Moving From Promis.e for AutoCAD to Promis.e Standalone
Product(s): Promis.e for AutoCAD Version(s): 3.0.x, 08.11.05.xx - 08.11.11.85 Environment: N/A Area: Migration Subarea: N/A Background As Promis.e for AutoCAD is no longer being developed and migration...
View ArticleForum Post: RE: Report Template Designer
Thank you for your help and support, much appreciated.
View ArticleForum Post: RE: ProjectWise Attribute Mapping security issue
Hello Matt, we are also having this same issue when we try and modify the project options. The project is stored on PW datasource. Has there been a resolution to this? We have SS8...
View ArticleForum Post: Can't use my .shx font !
Hello everyone, my company use this 1vni.shx font but it can't work in Bentley substation V8i series 7 It could work in text editor but when i click it to my drawing, it turn to be an error. Does...
View ArticleForum Post: To change the distance(gap) between 3 phase wires from the...
Hello All, I have a quick question. For the three phase wire, the distance between two phases is 5mm by default. Is there a way to increase the gap to 10mm(As shown below), becuase it is the standard...
View ArticleForum Post: RE: Can't use my .shx font !
Hi Christina, Can you try pasting the 1vni.shx file in the below location and then check if you get the Error Message. Location to insert the .shx file :- C:\ProgramData\Bentley\Substation...
View ArticleForum Post: RE: Can't use my .shx font !
Thank for your help, but it still have that error. This drawing was imported from a CAD drawing, I think that was the problem. But with your help, i could use this font, althought i couldn't modify...
View ArticleForum Post: RE: To change the distance(gap) between 3 phase wires from the...
I believe the phase spacing is configured with your drawing / project grid spacing.
View ArticleForum Post: RE: To change the distance(gap) between 3 phase wires from the...
Hi Vivek, You can change the same by changing the Grid Master value as per you requirement from Settings > Design File > Grid > Grid master . Regards, Satish Saptasagar
View ArticleForum Post: RE: Can't use my .shx font !
Turn out the problem was in shx big font field in text style! Problem solved. Thank you for your help!
View ArticleForum Post: RE: To change the distance(gap) between 3 phase wires from the...
if you want to change the drawing grid spacing, you have to go to settings, design file settings, and choose grid in the category tree. From my experience (which is limited) this setting will revert...
View ArticleForum Post: RE: To change the distance(gap) between 3 phase wires from the...
Thanks for the response. It worked as you mentioned but the component and the symbols are created with 5.00 grid spacing in mind. When I change it to something else, let's say 15, connecting the wires...
View ArticleForum Post: RE: To change the distance(gap) between 3 phase wires from the...
No problem, its helping me learn the program as well. I have to admit that I was changing the spacing to draw my 3 phase wires, and then changing it back to work on everything else. I'm not sure if...
View ArticleForum Post: RE: To change the distance(gap) between 3 phase wires from the...
Just to put a nice bow on what's already been said: the spacing between the wires drawn with the 3 Phase Wire tool is set to the active grid spacing. You can indeed change the active grid spacing by...
View ArticleForum Post: SIG Virtual Workshop: Bentley Electrical – May 8, 2018 – You're...
Staying current on innovative best practices and product updates for your Bentley electrical software is easier than ever! Make plans to attend the next Bentley Electrical Special Interest Group...
View ArticleForum Post: RE: ProjectWise Attribute Mapping security issue
Unfortunately, defect TFS 571370 is still open, and your company is already on the affected list. It looks like it may get resolved in an Update to the forthcoming CONNECT Edition release. Regarding...
View ArticleForum Post: How to solve this error message: Exception has been thrown by the...
Hi Everyone, When I open up my Substation software, I get the following error; after which I click OK and this error message pops up; How do I overcome this error? Thank you.
View Article