Forum Post: RE: can anyone help to resolve this issue ? [Unable to...
Hi Sofia, The information dialog indicates that the plugin is unable to place the macro in the drawing. It may be due to the macro not being in the location from where the plugin is configured to pick...
View ArticleForum Post: RE: can anyone help to resolve this issue ? [Unable to...
Hi Sarvesh, The error was popping out at the bottom of my page each time I run my GPL plugins. The result, yes the terminal function diagram came out, but I need to run a few time (until the software...
View ArticleComment on Promis.e V8i SS8 08.11.13.96 Readme File
uninstalled Promis.e and reinstalled still same error. Can you help!
View ArticleForum Post: BRCM Support manager
Hi all, We recently had training on BRCM SS2, we didn't cover the supports section, is there any documentation that covers that, as we are using BRCM for a large project and generating electrical models.
View ArticleForum Post: RE: BRCM Support manager
Hi Sicelo, You can refer the Help file for the same also for things related to Training you can refer to Below Wiki Link & and also Browse to Bentley Learn Server for videos on the same. Wiki Link...
View ArticleComment on Promis.e V8i SS8 08.11.13.96 Readme File
Hi Ray. Could you please post this question in this forum: https://communities.bentley.com/products/electrical___instrumentation/f/elcocad-promis-e-forum instead?
View ArticleForum Post: RE: Terminal/Pin-plug manager move up/down when device family is...
Hi WojtekM, I have created an enhancement request (TFS 899831) for the ability to move terminals in Terminal/Pin Plug Manager which have family assigned to them and added you to the requestor list....
View ArticleWiki Page: Network Installation Guide
Product(s): Promis.e, Bentley Substation Version(s): 08.11.10.xx - 08.11.13.140 Environment: N/A Area: Installation_Configuration Subarea: N/A For versions of Promis.e prior to promis.e V8i...
View ArticleWiki Page: Converting to an SQL Parts Database
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Database Platform Support Subarea: N/A Background With very large parts databases, some performance...
View ArticleForum Post: Page number TC_ gets duplicated in Graphical Plan Mode
Hi, I am using custom template for Graphical Plan: Some of my page numbers (TC_ ) gets duplicated as a result, but only some of them: Its getting duplicated also in IEC Standard Graphical plan: But not...
View ArticleForum Post: RE: Page number TC_ gets duplicated in Graphical Plan Mode
Hi Wojtek, Are you able to see the same in all the projects or a particular project. Also is it specific to a Particular Graphical Plan or to all. Regards, Satish Saptasagar
View ArticleForum Post: RE: Page number TC_ gets duplicated in Graphical Plan Mode
Hi Satish, it's related to few last projects, I suppose all that was started in SS8. But in meantime I have found the reason (if inexplicable). Page Number is duplicated for terminals, where Edit >...
View ArticleForum Post: New Installation
I just installed version 08.11.13.96 on my machine. On my older version of promise, I had two setup configurations. One for my local machine and one when I was in the office and connected to the...
View ArticleForum Post: RE: New Installation
Hi Ken, For the issue that you are facing, kindly refer the below mentioned Wiki Link. Troubleshooting Project Database Connection Problems:...
View ArticleForum Post: RE: New Installation
Hi Ken. If other users are also not able to connect to the network database, or you cannot connect using SQL Server Management Studio, I would check to make sure the SQL service is running on that...
View ArticleWiki Page: Raceway with high bend radius
Product(s): Bentley Raceway and Cable Management Version(s): 08.11.09.35 Environment: N\A Area: Dataset Subarea: N\A Problem Description I need to create a conduit catalog that includes fittings with...
View ArticleForum Post: Issue when publishing a project file.
While Promis.e is publishing my project i get this error message: Please help.
View ArticleForum Post: RE: Issue when publishing a project file.
Hi Edmund, The message that you are getting is similar to the one described in another forum post....
View ArticleForum Post: RE: Issue when publishing a project file.
Text of error message for searching purposes: Publisher System NullRefererceException Object reference rot set to an instance of an object. at ECT.ECAD.API.RowItem.get_Name() at...
View ArticleWiki Page: License Management Tool
Product(s): Promis.e, Bentley Substation, Bentley Raceway and Cable Management Version(s): through 10.00.00.232 Environment: N\A Area: Licensing Subarea: N\A Background The License Management Tool ,...
View Article