Wiki Page: Error - Specified DSN contains architecture mismatch

$
0
0
Product(s): Bentley Raceway and Cable Management Version(s): 08.11.07.xx Environment: N/A Area: Installation / Configuration Subarea: Error or Warning Message When trying to perform operations in a DGN file the following message appears: SQL Error The specified DSN contains an architecture mismatch between the Driver and Application Explanation This error can occur if the 64-bit odbcad32.exe is used to configure an ODBC data source that connects to a 32-bit driver. This typically occurs when Bentley Raceway and Cable Management (BRCM), which is a 32-bit application, is running on a 64-bit operating system and the data source is configured using Control Panel > "Data Sources (ODBC)" or by running \Windows\system32\odbcad32.exe How to Avoid To resolve the problem, delete the existing BRCM ODBC data source then run \Windows\SysWOW64\odbcad32.exe to create a new data source. This instance of odbcad32.exe is 32-bit, matching BRCM. Original Author: Matt_P