Forum Post: SQL Update Error (pes08111396en_updt1)
We received the following error while updating SQL and wondered if the errors are anything that needs resolving? I ask this because its mentioned that items already exist. For reference, we've used the...
View ArticleForum Post: RE: SQL Update Error (pes08111396en_updt1)
Hi Adam. Those messages do not occur for me. It sounds like the messages are occurring because the related Views were not able to be dropped by the script, so when the script tries to recreate them,...
View ArticleForum Post: RE: SQL Update Error (pes08111396en_updt1)
we've managed to resolve this and think it was down to either one of two things; 1- the database being in use while updating (unlikely, I didn't think that would cause an error like that?), 2-...
View ArticleForum Post: RE: Air Gap to Free Air
The developers said that the value in SPEC_AutoRouter.xml was not intended to be changed, and they cannot guarantee that air gaps will always be recognized as such if this value is changed. So we...
View ArticleForum Post: Promis.e 08.11.13.96 odd behavior with Symbol Creation Wizard
I have just updated Promis.e to 08.11.13.96. One thing I have noticed is that if I have a drawing sheet from a project open and I open up the symbol creation wizard, a new drawing window does not open....
View ArticleForum Post: RE: Promis.e 08.11.13.96 odd behavior with Symbol Creation Wizard
I do not have a machine that upgraded from 08.11.13.57 to 08.11.13.96 at the moment, but I did not immediately see the issue with my clean install of 08.11.13.96, so it does not appear to be some...
View ArticleForum Post: RE: Promis.e 08.11.13.96 odd behavior with Symbol Creation Wizard
It appears that the seed file was indeed missing. We use a customized seed file and it seems that when I applied the upgrade, our seed file was removed. I also found that my custom reports were also...
View ArticleForum Post: RE: Promis.e 08.11.13.96 odd behavior with Symbol Creation Wizard
Glad to hear the problem is solved Mitch. For other readers, we definitely recommend backing up your work and any customizations before upgrading. See also Updating and Upgrading Promis.e . When...
View ArticleWiki Page: Installing with no internet connection
Product(s): Promis.e, Bentley Substation Version(s): 08.11.11.xx - 08.11.13.96 Environment: N/A Area: Installation/Configuration Subarea: N/A Problem Description The installation program tries to...
View ArticleWiki Page: ProjectWise Configuration for BRCM
Product(s): Bentley Raceway and Cable Management Version(s): 08.11.09.35 Environment: N/A Area: ProjectWise Integration Subarea: N/A Background This article expands on the information provided in the...
View ArticleWiki Page: Network Installation Guide
Product(s): Promis.e, Bentley Substation Version(s): 08.11.10.xx - 08.11.13.96 Environment: N/A Area: Installation/Configuration Subarea: N/A For versions of Promis.e prior to promis.e V8i SELECTseries...
View ArticleWiki Page: Export construction drawings to PDF and DWG with small file size
Product(s): Bentley Substation Version(s): through 08.11.12.xx Environment: N/A Area: Platform Support Subarea: MicroStation Support Background Construction drawings typically have references of large,...
View ArticleForum Post: RE: Cross reference display while copying to different project
Hi Matt, any status on the updates?
View ArticleForum Post: RE: Cross reference display while copying to different project
Hi Dileep. Yes, Promis.e V8i SELECTseries 8 08.11.13.96 has been released and addresses this issue.
View ArticleWiki Page: Copy with base point to other pages
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.96 Environment: N/A Area: PowerPlatform Support Subarea: Manipulate Tools Background This document describes how to copy or move a...
View ArticleWiki Page: Error - Specified DSN contains architecture mismatch
Product(s): Bentley Raceway and Cable Management Version(s): 08.11.07.xx Environment: N/A Area: Installation / Configuration Subarea: Error or Warning Message When trying to perform operations in a DGN...
View ArticleWiki Page: Configure BRCM database connect string with no ODBC DSN required
Product(s): Bentley Raceway and Cable Management Version(s): through 08.11.09.35 Environment: N/A Area: Installation / Configuration Subarea: N/A Background This article describes how to configure a...
View ArticleForum Post: Error Message keeps on popping - Cannot create symbol. Please help !
I have a problem with my Promis.e & I always need to restart my PC as it always hangs. Once I tried to create symbol (based on another symbol) . I copied the symbol from an existing project &...
View ArticleForum Post: RE: Error Message keeps on popping - Cannot create symbol. Please...
Text of error messages for searching purposes: Alert UI Fail to delete folder. The process cannot access the file 'C:\Users\DELL PC\AppData\Local\Temp\tmpAB4C.tmp' because it is being used by another...