Quantcast
Channel: [Archived] elcoCAD | Promis.e
Viewing all articles
Browse latest Browse all 3874

Wiki Page: Resolved issues in Bentley Raceway and Cable Management CONNECT Edition, 10.00.00.127

$
0
0
Product: Bentley Raceway and Cable Management Generation: CONNECT Edition Version: 10.00.00.127 Defect Number Description 911638 The software crashes when double clicking a routing line to navigate to a raceway dng file when integrated with ProjectWise. 911640 The software crashed when using the navigate tool to navigate to a raceway/equipment dng file when integrated with ProjectWise. 921419 In a particular project, selecting any routed cable would result in an unhandled exception error. 909146 An unhandled exception error would occur if you tried to delete a voltage level item in the Options>Raceway Specifications>Raceway Categories dialog. 151961 Corrected a message box displayed when previewing or exporting a report that stated, "Cable Manager Loading data…" The message now properly refers to the "Output Manager" instead of the "Cable Manager." 759383 When placing a manhole using the Equipment Manager, the measured inside height should match the specified Inside Height and the measured outside height should equal Inside Height + 2 x Wall Depth. 741451 When inserting a raceway bend and connecting it to a straight the raceway guid value of the bend would become duplicated with that of the straight piece rather than being assigned an unique value. 889496 The Detail_Cable_Route_List report when run on a particular project reported all lengths as 2.0 and did not include the raceway IDs in the RW Segment ID column. 910158 Fixed the incorrect Reducer Lengths for the Cooper Cable Ladder Series 2,3,4 & 5 Steel catalog 633478 The performance of various operations in the Cable Manager have been improved which include, loading data, Auto Connect, loading Routing Manager, closing Routing Manager, Save to Project Model, Refresh Routing Model, and reopening the Cable Manager after routing is performed. 361450 Repeated raceway part creation would continually increase the memory usage until the software would crash. 652968 Publish_i-model could not create relationships between cables and other elements in the demo project BRCM_PLANT_US_COMP. 709750 The BRCM Tools > Display Manager dialog had labels that could not be localized in other languages. 614827 iModel publishing failed for a particular project. 492213 Executing 'Reroute Cables with lower Priority’ in the Routing Manager multiple times will produce an error or crash BRCM when you attempt to exit the Routing Manager. 902505 The Conceptual Design BOQ report is empty and the Length in the Conceptual_Cable_Schedules is zero when using the Conceptual Design Sample project. 637262 Updates to raceway IDs were not reflected in the Cable Manager and outputs unless you performed a new automatic routing which is not always desirable. 867859 Raceway that does not match the Context ID in the LIB_Raceway.xml was appearing by default in the Raceway Router or Duct Bank Router dialogs by mistake. 374441 The Tee fitting for the Generic Cable Tray Square raceway should not have a radius. 289520 When selecting Refresh Routing Model a status box was displayed which remained on the top of all other application windows. The status box should not be displayed on top of other unrelated applications so that it doesn't impede users from working in other applications while they wait for the command to finish. 656736 After Duct bank is copied, the ID cannot be modified and the duct bank cannot be stretched. 374242 In certain scenarios the Duct Bank Router > Connect command when using the branch option is unable to insert parts such as elbows on the selected conduits. 626673 Unable to add new raceway specs in Conceptual design. 947068 In the Raceway Catalog Creation dialog, an error appeared when adding a raceway size and pressing Enter. 947520 The Raceway Offset tool could crash the software when selecting a MV voltage level in the Raceway Properties grid. 947577 In the Raceway Router dialog, double clicking on Dividers and then setting focus to the Voltage Level cell could cause the software to crash. 816269 In the Chinese build, the software cannot generate 3D Cable visualization after importing the database xml files. 378258 Using the Raceway Catalog Creation tool to define fittings could result in incorrect chamfer and end straight lengths on vertical bend fittings. 903656 The 2D Extraction raceway labels were displaying the wrong weight and height values such as 3 instead of 300mm. 709747 Some labels in the Create New Raceway Catalog were not localizable in other languages. 867855 The Add, Copy, Paste & Delete buttons in the Equipment Manager were disabled in the Chinese localized build. 867901 If you attempted to create new equipment using a template and then tried to edit Equipment Properties an error occurred and the equipment was not created. 390666 When routing raceway and inserting a cross over fitting the variants list ends up with duplicate entries in it. 722422 The Excel import and i-model import for cable lists result in an exception error regarding missed resources. 665853 When using the Validate Active Dataset command and no error was found an awkwardly worded message was displayed. 344768 An "Incompatible item type libraries" message was displayed when publishing an i-model. 874904 Selecting multiple objects and right clicking DisplaySet clears the selection set rather than executing the command. 921096 The software crashed when updating the existing 2D section 3 in the example project BRCM_PLANT_US_Comp. 639120 The path to the EC schema files such as ECClasses.xml was hard coded, but should be configurable. 569741 The Trade width for raceway tees ($TT) does not work correctly in descriptions on reports. 562104 There are the wrong fittings defined in catalog 'Rico Wide Span Cable Ladder System 150'. All bends, tees, crossovers have to be round and not square, as well as defined in 'Rico Wide Span Cable Ladder System 200' for example. 423891 When integrated with ProjectWise and you attempted to use the Output Manager to export a report you were prompted two times to specify the ProjectWise Path for the report and it did not default to the correct path. The software should now present a dialog to save the file in the folder specified by the BRCM_PW_SUBFOLDER_REPORTS variable first. If the user selects Cancel, then a dialog to save in the local file system is presented. 179736 Schedule 80 conduits don't have correct body style Tee fitting.

Viewing all articles
Browse latest Browse all 3874

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>