Forum Post: RE: Is it possible to have 2 pages open at the same time?

Hi Tim, View is the Bentley's free DGN/DWG viewer. You can download it at https://select.bentley.com/FulfillmentCenter/ Promis.e save each page in separate DGN file. As View opens DGN files in...

View Article


Wiki Page: Compatibility Chart - Bentley Substation

Product(s): Bentley Substation Version(s): 08.11.10 - 10.02.00.31 Environment: N/A Area: Installation_Configuration Subarea: N/A The purpose of this document is to indicate the compatibility of various...

View Article


Forum Post: RE: Is it possible to have 2 pages open at the same time?

yes it is definitely possible bluestacks .

View Article

Wiki Page: Alert - UI Fail to delete folder

Product(s): Promis.e, Bentley Substation Version(s): 08.11.13.96 Environment: N/A Area: Installation_Configuration Subarea: N/A Error or Warning Message When loading the Project Manager tree, the...

View Article

Wiki Page: How to Install Bentley Substation

Product(s): Bentley Substation Version(s): through 08.11.13.140 Environment: N/A Area: Installation_Configuration Subarea: N/A Steps to Accomplish Installation Steps for V8i: Please refer [[How to...

View Article


Forum Post: Objects in families has lost their connections

Hi, during normal work, something very bad happen. Every project is broken. I have project in several databases, in each database is the same. Tried to create fresh one and restore projects, no help....

View Article

Forum Post: RE: promise database completely broken

Hi Wojtek, Can you elaborate on what happening when you say "Every Project is Broken" are you not able to work on any projects in Promis.e? Are you facing issue only with Family, for the Family symbol...

View Article

Forum Post: RE: promise database completely broken

Hi Satish, yes, I am not able to work on any project. Each project has the same issue. It's about all families. Device usage chart shows only a part: While Place symbol by DeviceID shows them all (and...

View Article


Forum Post: RE: promise database completely broken

Hi Wojtek, Can you let us know if this Catalog is a network Catalogue or a local Catalogue, Can you try Rebuild Catalog or Refresh Catalog and then check if it helps with the issue you are facing....

View Article


Forum Post: RE: promise database completely broken

That's local catalog. Rebuilding catalogue doesn't help. Some other things I have checked: 1. I am able to place a child using "Place symbol by DeviceID". Xref to that child is propagated properly over...

View Article

Forum Post: RE: promise database completely broken

Hi Wojtek, Can you upload you Project & Catalog backup on by following the steps provided in the below Wiki Link, We will try to investigate the issue on our side by using the your project &...

View Article

Forum Post: RE: promise database completely broken

Done.

View Article

Wiki Page: How to configure BRCM on network location

Product(s): Bentley Raceway and Cable Management Version(s): through 08.11.09.35 Environment: N/A Area: Installation_Configuration Subarea: N/A Background During Project activities user may need to...

View Article


Forum Post: RE: promise database completely broken

Hi Satish, tried to: 1. Remove Promise 2. Manually delete all remaining folders, like: C:\Program Files (x86)\Bentley\Promise V8i C:\Users\hallm\AppData\Roaming\Bentley (promis.e subfolders)...

View Article

Forum Post: RE: Objects in families has lost their connections

Hi Wojtek, Thank you for the update, It looks like Clean Install helped with the issue you are facing. Can you upload the file again on the below share file link and we will update you after we restore...

View Article


Wiki Page: Import Catalog

Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.96 Environment: N/A Area: Component Management Subarea: Catalog Manager Background The Import Catalog tool restores catalogs from...

View Article

Forum Post: Wire Links automatically renumbering

We've had a recurring incident where all wire links have automatically renumbered themselves back to the default tags Lxx. This is happened to the same user before on another project. Other uses have...

View Article


Forum Post: RE: Wire Links automatically renumbering

*edit* what also appears to have happened is the same with the terminal numbers, these have been reset and renumbered and we also have duplicated terminals. I.e X2-1 and X2-2 are shown on pages 3102...

View Article

Forum Post: RE: Wire Links automatically renumbering

Hi Adam, Please take back up of project and then share in that link . Wiki link for Back up of Project :- Regards, Avanti

View Article

Forum Post: RE: Wire Links automatically renumbering

Hi Avanti Khandalkar , Backup of the project is in my original message. Please let me know if you require anything further.

View Article