Hi Elango, Can you please go through this Document , this might help you, PowerDraft Shortcut Setup.pdf Regards, Avanti Khandalkar
↧
Forum Post: RE: I need to know the Promise V8i keyboard shortcuts
↧
Forum Post: RE: RSALG VS ALG
Hi Avanti i see two issues. 1. If I copy and convert the ALG into RSALG, the file will no longer be updated by the track engineers. I risk designing signals on a outdated track design. I would be better if I designed directly on top of the live an updated ALG. 2. If I choose the copy solution described above, what happens with my signal design when evetually changing the an outdated RSALG wih a updated RSALG? /Lennart
↧
↧
Forum Post: RE: I need to know the Promise V8i keyboard shortcuts
thanks for response. how do i get the shortcut.txt file
↧
Forum Post: RE: I need to know the Promise V8i keyboard shortcuts
Hi Elango, You can try using the Key mapping in Promis.e by selecting the Key according to the what is displayed on the screen. For an e.g you can refer the below image where for opening Catalog Manager you select "E" key on the keyboard and then select "1" for catalog manager the Key for function can be seen on the left side of the function. Hope the above suggestion helps. Regards, Satish Saptasagar
↧
Forum Post: RE: Thumbnail view in project Manager - How to increase size & how to show full extents of each drawing page?
Hi Doug, It is not possible to show the complete drawing page within each thumbnail as the feature is not available in Promis.e CONNECT. You need to directly open the drawing page to view and work on the drawing.
↧
↧
Forum Post: RE: Thumbnail view in project Manager - How to increase size & how to show full extents of each drawing page?
Hi Lalitesh, I think you may have misunderstood me. When I said I want to show the complete drawing within the thumbnail I meant that all of my thumbnails are off centre. A thumbnail is a smaller version of an original image, but it does need to capture the complete original. In this example, each of the six thumbnails shown is missing the right hand section of the orignial drawing and there is empty space on the left. Is there no way to get promise to regenerate the thumbnail images so the border is in the centre and I get the full extents of the drawing shown like this example below? Regards, Doug
↧
Forum Post: RE: Thumbnail view in project Manager - How to increase size & how to show full extents of each drawing page?
Hi Doug, For displaying the full extents of drawing in the thumbnails , you can try clicking on Fit view tool to adjust the view of the drawing page. Also , you can adjust the view of the drawing by moving the mouse scroll back and forth to zoom in/out the view of drawing page. In the thumbnail view of the page , it will display the page according to the view set from the scroll button of the mouse. So, in the last saved view of the page is displayed in the thumbnail view. You can try adjusting the view by using the mouse scroll. The same view will be available in the thumbnail. Hope this helps.
↧
Forum Post: RE: Thumbnail view in project Manager - How to increase size & how to show full extents of each drawing page?
Hello Lalitesh, I started a new project and tried your suggestions, to get the three following thumbnails, I had to place the contents of each drawing on the left of my screen, I'm going to give up on the thumbnail view, it seems broken to me, and it's not that important anyway. Thanks for your support. Doug
↧
Forum Post: RE: I need to know the Promise V8i keyboard shortcuts
yes it works thanks
↧
↧
Wiki Page: How to Configure Wire Label in Promis.e CONNECT and Bentley Substation CONNECT
Product(s): Promis.e, Bentley Substation Version(s): 10.02.00.29 Environment: N/A Area: Wire Numbering Subarea: Modify Wire Label After assigning a wire number, how to configure Wire Label in Promis.e Connect ? Background The Automatic Wire Numbering is used to assign wire number to Entire Project, Page or Select objects Automatically. The users while doing the same might have specific requirements on how the Wire Number Label looks. For Example, In the wire number user want to add Installation and Location or Adding Current and some other information then need to set this configuration from Project Option. This document provides steps to Configure Wire Label. Steps to Accomplish In Project Manager, Click Options > Wire settings > Label Preferences then select Edit under Specify Tag formats for different type of connections for Wire Tag(only) as seen in the below image. Click Wire Label Display, Browse Edit. In Wire Label Display dialog, select Add to Expression to add attribute present in Left dialog to Right dialog to create formula. For example: - Wire Tag, Current, User1 according to requirement. Verify Results: Check and verify the Wire Numbers Wire tag is 4, Colour is BLU and User1 is blank . Original Author: Avanti Khandalkar Keywords: wire tag
↧
Forum Post: Unable to calculate cable sag. Some parameter values may not be valid...
I am unable to insert a cable and receive the following error: " This just started happening and I need this resolved ASAP. I am currently running Bentley Substation CONNECT Update 3. Thanks!
↧
Forum Post: RE: Unable to calculate cable sag. Some parameter values may not be valid...
Hi Huskey, Are you facing the issue the issue while placing the cable on a particular equipment or for all the Equipment in a project ? Regards, Satish Saptasagar
↧
Forum Post: RE: Unable to calculate cable sag. Some parameter values may not be valid...
Hi Huskey, Also can you let us the Sag Algorithm and the Parameter Value that your are entering for the Sag Calculation. Regards, Satish Saptasagar
↧
↧
Forum Post: RE: Unable to calculate cable sag. Some parameter values may not be valid...
Hi, Satish. I am encountering the issue throughout all my projects. I have tried multiple part numbers, both client created and Bentley provided, and still encounter the issue. See below for screenshot of the parameter value:
↧
Forum Post: RE: Unable to calculate cable sag. Some parameter values may not be valid...
Hi Huskey, Have you tried changing the Offset value for the Sag and check if you are able to place the cable, may be reduce the value and check if it help ? Also how far are the Equipment Hook Point for which you are placing the cable. Regards, Satish Saptasagar
↧
Wiki Page: Minimum SQL user permissions
Product(s): Promis.e, Bentley Substation Version(s): through 08.11.13.73 Environment: N\A Area: Database Platform Support Subarea: N/A What are the minimum permissions required for a user to successfully connect and use a SQL project database with promis.e or Bentley Substation? Background This article is intended for SQL server administrators. When the ecaduser login is created by the software or a login is created with the script provided in the [[Creating an SQL Server Login]] article, the login will be a member of the public server role and the db_owner and public database roles. Alternatively, the db_datareader and db_datawriter database roles can be assigned instead of db_owner , as described below. Steps to Accomplish In SQL Server Management Studio , connect to the server. SQL Management Studio if not installed on your machine then follow the Wiki Link Install SQL Server Management Studio for the details steps for installing SQL Management Studio. In the Object Explorer tree expand Security > Logins . Create the login if it does not already exist by Right Click on Login and Select New Login . If need to make changes to existing Login, Right-click the existing User login and select Properties . On the Server Roles page enable the following: public On the User Mapping page, select the database used by the software in the Database column. Specify "dbo" in the Default Schema column. In the "Database role membership" area enable: db_datareader db_datawriter public Or enable: db_owner public Disable: db_denydatareader db_denydatawriter Click OK . Right-click the project database in the Object Explorer tree and select Properties . Select the Permissions page. Select the user in the top pane. Check the box in the Grant column for the Execute permission in the bottom pane. Click OK . See Also [[Creating an SQL Server Login]] [[Exception thrown when creating a project due to SQL permissions]] Original Author: Matt_P Keywords: rights, requirement, restricted, limited
↧
Wiki Page: Database Platform Support
.
↧
↧
Wiki Page: Creating and Updating the Project Database - Substation CE
Product(s): Substation CONNECT Version(s): 10.00.XX.XX to 10.05.XX.XX Environment: N/A Area: Installation_Configuration Subarea: N/A Background Substation uses database to store project related information. Substation stores all the Projects details in a SQL Database. And one Project Database can store details for several Projects. While installing Substation CONNECT Edition by default a SQL Server Express is installed with SQL Server (local)\BENTLEYECAD and after first run Substation will try to create Project Database substation . Each version of the Substation has its own corresponding database schema and "version" number property. When creating or updating the project database using Script, be sure the source material will create or update the database with the correct version number. For example, using a script from the program folder of the software version x will not necessarily create/update the database to a version compatible with the software version y. If the database is created/updated from different media than the version of the software being used, a "Database version does not match the application" message will display when trying to connect to the database in the software. If the media is older, the database schema will then have to be updated. If the media is newer, the software will need to be updated. Note: The "Executing a Script" methods are recommended when the project database is hosted by SQL Server running on a different machine than the workstation. Create the Database Method 1: Project Database Utility Create the Database Method 2: Executing a Script Update the Database Method 1: Project Database Utility Update the Database Method 2: Executing a Script For Creating Database, you need to have Compatible SQL Server installed and running. SQL Express Server can also be downloaded from Microsoft and installed independently of the software. See Installing SQL Server for more information. And the Compatibility Chart – Substation CONNECT Note: For Creating / Updating Database the user needs to have sysadmin in the SQL Login user under Server Roles. You can follow the below Wiki Link for adding Minimum SQL User Permission . Create the Database Method 1: Project Database Utility 1. For opening Project Database Utility go to File>> Configure Database >> New Database. 2. Next in the Project Database Utility dialog select the Server >> Authentication Method for logging into the SQL Database >> Specify Database Name >> Select Detect >> Select Test Connection >> select Execute Script . Server Name The server name format is MACHINENAME\INSTANCENAME. If creating a database on the local workstation, "(local)" can be substituted for the machine name. For non-Express versions of SQL Server there will be no backslash and no instance name. The SQL Server Configuration Manager can be used to determine the names of existing SQL Server instances. On the machine where the SQL Server that is to host the database is installed, run this program by selecting running SQL Server Configuration Manager application. Then click on Services in the left pane of the SQL Server Configuration Manager and note the instance name(s) listed in the right pane. For example, a service called "SQL Server (BENTLEYECAD)" indicates that there is an instance named BENTLEYECAD installed. Authentication A login with administrator privileges must be used when attempting to create a database, whether Windows or SQL Server authentication is selected. Windows Authentication When this option is enabled the utility will try to connect to the SQL Server using the credentials of the Windows user account in which the utility is currently running. If the current Windows account was used to install SQL Server, then Windows Authentication is likely to work. Otherwise, the current Windows account would have had to have been added as a SQL Server Administrator on the Database Engine Configuration step of SQL Server installation or afterwards with SQL Server management software. Server Authentication To use this option the SA password must be known. With this option, a more general SQL login can be created for the users with the Username and Password fields on the Project Database Utility dialog. SA password This password is specified during SQL Server installation and is not required when using Windows Authentication. Database Name As configured in the screen shot of the Project Database Utility dialog above, the utility would create a database named " substation " attached to the BENTLEYECAD instance of the local SQL Express Server. If a "substation" database already exists on the server, use a different name such as " substation1 ". The standard name for a project database for Bentley Substation is "Substation". See Rules for Regular Identifiers regarding acceptable database names. SQL Server Management Studio (including Express) can be used to verify the names of existing databases. The figure below shows a database named "substation" in the Object Explorer window of SQL Server Management Studio Express. Datafile Path On the Project Database Utility dialog, the path specified in the Datafile Path field is where the database file and transaction log will be created. Once a valid server name is entered into the Server Name field, click the Detect button to populate the Datafile Path field with the correct path. Alternatively, the [...] button can be used to browse for the desired folder. A typical path for SQL Server 2014 with a BENTLEYECAD instance is C:\Program Files (x86)\Microsoft SQL Server\MSSQL12.BENTLEYECAD\MSSQL\DATA Specifying the path to the Promis.e program folder or the promis-e Data folder or the corresponding Substation folders for the Datafile Path field is not recommended since it would result in the loss of the database should the folder be deleted as part of a reinstallation process. Username To create a SQL login (as opposed to using a Windows login) that the software can use to connect to the database, enter the desired name in this field. For example Bentley Substation have historically used "ecaduser" for the SQL Login name. The SQL login can be used by multiple users. This field is only available when the Server Authentication option is enabled. Password Specify a password to be used with the login/username that will be created if using Server Authentication. Confirm Password Enter the same password as entered into the Password field. Test Connection button After configuring the parameters on the Create Project Database tab, click the Test Connection button. If the utility determines the parameters on the dialog are acceptable, a confirmation message is displayed in the message window and the Execute Script button will become available. Otherwise, see the message display area for reasons why the test failed. Execute Script button Click the Execute Script button to create the database. A separate command window will open as the database is created. When this window closes itself, click the Close button on the Project Database Utility to return to CONNECT Edition's New Project dialog or V8i's Setup dialog, which will be populated with the newly created database name and other associated settings. Create the Database Method 2: Executing a Script The project database can also be created by modifying and executing the SqlServerProject.sql script using SQL Server Management Studio, sqlcmd, or the osql utility. When the database is to be created on a machine other than the workstation, the script can be copied to the server machine from the workstation that has Bentley Substation installed, then executed by the database administrator. For this example, the script will be executed using SQL Server Management Studio, which is normally installed when SQL Server 2014 R2 is installed via the Promis.e or Bentley Substation package, unless the Management Tools feature was declined during installation. SQL Server Management Studio will need to be downloaded from Microsoft and installed separately when SQL Server 2014 is provided with the Bentley Substation package. Note: This method only creates a project database. SQL Server must already be installed and running. Note: This method only creates a project database. SQL Server must already be installed and running. In CONNECT Edition, the script SqlServerProject.sql can be found in the " Substation CONNECT program folder \ Electrical \ SqlScripts" and in the ". If the file cannot be found, perform a search. Make a backup copy of the script before modifying it. 1. Navigate to the script file in Windows Explorer and double click it. On machines where SQL Server Management Studio is installed, double clicking on a .sql file will open it in SQL Server Management Studio. 2. When the Connect To Database window appears, enter the name of the server machine and instance where the database to be updated resides in the format MACHINENAME\INSTANCENAME. Consulting the Configure Database tab which may help determine what should be entered here. Select the appropriate Authentication method, then click Connect. 3. Regarding acceptable database names. The text highlighted yellow shows where the database name must be inserted. DO NOT USE FIND AND REPLACE to replace all instances of this text throughout the script or you will introduce an error by replacing too many instances of this text. Only replace the ones indicated. 4. The "$ShortProductName$" value in the last line of the excerpt must be changed to Substation for the Bentley Substation software, regardless of the name of database, and it is case-sensitive. The correct value for Promis.e is shown highlighted in magenta in the excerpt below. 5. Modify the paths for the database and transaction log files to reflect the true path to be used. A typical path for SQL Server 2014 is C:\Program Files (x86)\Microsoft SQL Server\MSSQL12.BENTLEYECAD\MSSQL\DATA The paths are highlighted in cyan in the script excerpt below but the correct paths may be different than shown. The Finding the SQL Data folder solution may be helpful. Note: Executing the script will not create any folders in the specified path. All folders in the path must exist at the time the script is executed. 6. After making the necessary changes, click the Execute button. Script Excerpt use master GO CREATE DATABASE substation ON (NAME = N' substation ',FILENAME = N' C:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\Data \ substation .mdf',SIZE = 200,FILEGROWTH = 40%) LOG ON (NAME = N' substation _log',FILENAME = N 'C:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\Data \ substation _log.ldf',SIZE = 80,MAXSIZE = 2048,FILEGROWTH = 20%) GO ALTER DATABASE substation SET AUTO_SHRINK OFF GO ALTER DATABASE substation SET RECOVERY SIMPLE GO use substation GO ALTER DATABASE substation SET AUTO_CLOSE OFF GO SET QUOTED_IDENTIFIER ON GO --********************************************************************-- if exists (select * from master..sysdatabases WHERE name=N' substation ') begin CREATE TABLE Project ( id int IDENTITY (1, 1) NOT NULL, name nvarchar(255) NOT NULL, anum nvarchar(255) NULL, templatename nvarchar(255) NULL, username nvarchar(50) NULL, date_create datetime NOT NULL, version nvarchar(255) NULL, prjpath nvarchar(1000) NULL, guid nvarchar(50) NULL, ModifyTime datetime NULL, ConnectionBuildTime datetime NULL, isLock int NULL DEFAULT 0, refid int NULL, LockUserName nvarchar(50) NULL, CONSTRAINT PK_Project PRIMARY KEY (id) ); EXEC sp_addextendedproperty 'Version', '10.0.11', 'user', dbo, 'table', project; EXEC sp_addextendedproperty 'ShortProductName', ' substation ', 'user', dbo, 'table', project; Update the Database Method 1: Project Database Utility To update a database attached to SQL Server running on a machine other than the workstation, the Execute a Script method typically works better. When connecting to an outdated project database by opening an existing project or creating a new project after upgrading the software, the software will prompt to update the database. If accepted, the Project Database Utility will open to the "Upgrade Project Database" tab. 1. For opening Update Project Database utility go to File >> Configure Database >> New Database >> Update Project database . If the server name or instance name entered for Server Name is incorrect (does not exist) a message such as the following will appear in the message area: Upgrade Error: A network related or instance-specific error occurred while establishing a connection to SQL Server. The server was not found or was not accessible. Verify that the instance name is correct and that SQL Server is configured to allow remote connections. If the database specified in the Database field does not exist, a message such as the following will appear in the message area: Upgrade Error: Cannot open database "database" requested by the login. The login failed. If the incorrect Login name or Password were entered, a message such as the following will appear in the message area: Upgrade Error: Login failed for user 'login name specified'. Please check MS-SQLServer Login info. 2. If all the settings are valid when the Upgrade Database button is clicked, a prompt will appear to optionally backup the database. Click Yes or No . Consider electing to backup the database if current backups of the projects have not been made. 3. An "Are you sure you want to upgrade the database?" prompt will be displayed. Click Yes to accept. 4. A separate command window will open as the database is updated. When this window closes itself, click the Close button on the Project Database Utility. Update the Database Method 2: Executing a Script Execute the SQL_UpdateDB.sql script using SQL Server Management Studio, or sqlcmd or the osql utility. When the database to be updated is attached to SQL Server running on a machine other than the workstation, the script can be copied to the server machine from the workstation that has Promis.e/Bentley Substation installed, then executed by the database administrator. When using this method to update a project database shared between multiple users, be sure the version of the Substation software installed on the workstation being used matches the desired database version. In CONNECT Edition, the script SQL_UpdateDB.sql can be found in the " Substation CONNECT program folder \ Electrical \ SqlScripts" and in the ". If the file cannot be found, perform a search. Make a backup copy of the script before modifying it. For this example, the script will be executed using SQL Server Management Studio, which is normally installed when SQL Server 2014 R2 is installed via the Promis.e or Bentley Substation package, unless the Management Tools feature was declined during installation . SQL Server Management Studio will need to be downloaded from Microsoft and installed separately when SQL Server 2014 is provided with the Bentley Substation package. 1. Navigate to the script file in Windows Explorer and double click it. On machines where SQL Server Management Studio is installed, double clicking on a .sql file will open it in SQL Server Management Studio. 2. When the Connect To Database window appears, enter the name of the server machine and instance where the database to be updated resides in the format MACHINENAME\INSTANCENAME. Consulting the Configure Database tab which may help determine what should be entered here. Select the appropriate Authentication method, then click Connect. 3. When the script opens, find the following line: use [$ShortProductName$] Change $ShortProductName$ to the name of the database to be updated. For example, to update a database named "substation1", the line should be changed to the following: use substation1 4. Next find the below line and: ALTER DATABASE $ShortProductName$ SET AUTO_SHRINK OFF Change $ShortProductName$ to the name of the database to be updated. For example, to update a database named "substation1", the line should be changed to the following: ALTER DATABASE substation SET AUTO_SHRINK OFF 5.Find the following line: EXEC sp_addextendedproperty 'ShortProductName', '$ShortProductName$', 'user', dbo, 'table', project; For Bentley Substation, change $ShortProductName$ in that line to Substation regardless of the name of the database being updated: EXEC sp_addextendedproperty 'ShortProductName', 'Substation', 'user', dbo, 'table', project; 6.Click the Execute button to execute the script. See Also Original Author: Satish Saptasagar
↧
Forum Post: Bentley 3D Substation BOM
How can I create a BOM/Report on just a section of a substation or of a single page within the project. Is this possible with the "ELEMENT SELECTION" key or by fence or per page rather than BOM Quantified or any of those pre-setup BOM/Report layouts. If I reference just a small part of the substation into a sheet can I run a Report just on that. If so How doe I do this?
↧
Forum Post: RE: Bentley 3D Substation BOM
Hi Johan, You can run filter on for the BOM Reports for a particular page or any other filter that is available. You follow the below steps for the same. Reports and Graphical plan >> Run Reports ( Wiki Link as below) >> Select the Report >> Filter and select the Field , relation ship and Value according to the requirement. For reference are you using an Substation DGN as a reference file ? Regards, Satish Saptasagar
↧